Pressure sensors Vacuum sensors – Use in hazardous areas
Product | Measuring range | Process connection | Output signal | Electrical design | Medium temperature | |
---|---|---|---|---|---|---|
PI003A | -1…25 bar -14.4…362.7 psi -0.1…2.5 MPa |
G 1 external thread sealing cone | switching signal; analogue signal; (configurable) | PNP/NPN | -20…60; (when used outside the hazardous area:; Ambient temperature: -25…85 °C; Medium temperature: -25…125 °C / 145 °C < 1h) °C | |
PI009A | -1…1 bar -1000…1000 mbar |
G 1 external thread sealing cone | switching signal; analogue signal; (configurable) | PNP/NPN | -20…60; (when used outside the hazardous area:; Ambient temperature: -25…85 °C; Medium temperature: -25…125 °C / 145 °C < 1h) °C | |
PI008A | -0.0124…0.25 bar -12.4…250 mbar |
G 1 external thread sealing cone | switching signal; analogue signal; (configurable) | PNP/NPN | -20…60; (when used outside the hazardous area:; Ambient temperature: -25…85 °C; Medium temperature: -25…125 °C / 145 °C < 1h) °C | |
PN004A | -1…10 bar -14.5…145 psi -100…1000 kPa -0.1…1 MPa |
G 1/4 internal thread | switching signal; analogue signal; (configurable) | PNP | -20…60 °C | |
PN006A | 0…2.5 bar 0…2500 mbar 0…36.3 psi 0…250 kPa |
G 1/4 internal thread | switching signal; analogue signal; (configurable) | PNP | -20…60 °C | |
PN014A | -1…10 bar -14.5…145 psi -100…1000 kPa -0.1…1 MPa |
G 1/4 internal thread | switching signal; IO-Link; (configurable) | PNP/NPN | -20…60 °C | |
PN016A | 0…2.5 bar 0…2500 mbar 0…36.3 psi 0…250 kPa |
G 1/4 internal thread | switching signal; IO-Link; (configurable) | PNP/NPN | -20…60 °C | |
PN007A | 0…1 bar 0…1000 mbar |
G 1/4 internal thread | switching signal; analogue signal; (configurable) | PNP | -20…60 °C | |
PN009A | -1…0 bar -1000…0 mbar |
G 1/4 internal thread | switching signal; analogue signal; (configurable) | PNP | -20…60 °C |