Cognex Area Scan Camera 3D-A5000

Posted on Posted in Cognex 3D Machine Vision Systems

 

3D Area Scan Camera Cognex-  3D-A5000 Models
3D-A5120 3D-A5060 3D-A5030 3D-A5005
Standard Working Volume
Clearance Distance (CD) 1000.0 mm 1400.0 mm 1465.0 mm 299.3 mm
Measurement Range (MR) 1000.0 mm 400.0 mm 80.0 mm 12.0 mm
Near FOV 900 x 675 mm 520 x 390 mm 280 x 210 mm 60 x 44 mm
Far FOV 1760 x 1320 mm 645 x 490 mm 285 x 216 mm 65 x 46 mm
Resolution XY 626–1223 μm 361–454 μm 195–200 μm 42–44 μm
Resolution Z 414–1656 μm 338–559 µm 178–198 µm 7–8 µm
Repeatability Z (σ) 250–1000 μm 100–150 μm 55–66 μm 5–6 μm
Extended Working Volume
Clearance Distance (CD) 800.0 mm 1200.0 mm 1415.0 mm 290.3 mm
Measurement Range (MR) 2000.0 mm 800.0 mm 190.0 mm 30.0 mm
Near FOV 720 x 540 mm 415 x 325 mm 250 x 180 mm 54 x 42 mm
Far FOV 2448 x 1836 mm 685 x 530 mm 290 x 220 mm 60 x 45 mm
Resolution XY 506–1701 μm 315–500 μm 191–204 μm 41–45 μm
Resolution Z 265–3246 μm 248–690 µm 166–213 µm 7–8 µm
Repeatability Z (σ) 250–2000 μm 120–250 μm 80–110 μm 7 μm

 3D-A5000 specifications
Dimensions 324 x 137 x 97 mm
Weight 3.0 kg
Operating Temperature 0–40 °C (32–104 °F)
Storage Temperature -10–60 °C (14–140 °F)
Operating Humidity <85% (non-condensing)
Protection IP65
Shock 50 gs (11 ms half-sine pulse)
Vibration 4 gs (10–120 Hz for 30 minutes)
Trigger Trigger input voltage limits: -24 VDC – +24 VDC
Input ON: > 10 VDC (>6 mA)
Input OFF: < 2 VDC (<1.5 mA)
Power Voltage: +24 VDC (22–26 VDC)
Current: 6.0 A max
Acquisition Time 200 msec
Software VisionPro
Ethernet 10 Gigabit Ethernet interface
Certifications CE, FCC, KCC, TUV SUD NRTL, RoHS
Optional Accessory Fan